PE Rabbit anti-Human CD10 mAb (100 T)

PE Rabbit anti-Human CD10 mAb (100 T)

Brand: Abclonal
Cat. #: A25723
Availability: In Stock
$218.00
-+
Reactivity: Human    
Applications: FC    
Host Species: Rabbit    
Isotype: IgG    
Clonality: Monoclonal Antibody    
Conjugation: PE. Ex:565nm. Em:574nm.
Gene Name: membrane metalloendopeptidase
Gene Symbol: MME
Synonyms: NEP; SFE; CD10; CALLA; CMT2T; SCA43
Gene ID: 4311
UniProt ID: P08473
Clone ID: 2J2S1
Immunogen: Recombinant fusion protein containing a sequence corresponding to amino acids 52-750 of human CD10 (NP_000893.2).
Dilution: FC,5 μl per 10^6 cells in 100 μl volume
Purification Method: Affinity purification
Concentration: 0.04 mg/mL
Buffer: PBS with 0.03% proclin300,0.2% BSA, pH7.3.
Storage: Store at -20°C. Avoid freeze / thaw cycles.
Documents: Manual-MME Antibody




Background

The protein encoded by this gene is a type II transmembrane glycoprotein and a common acute lymphocytic leukemia antigen that is an important cell surface marker in the diagnosis of human acute lymphocytic leukemia (ALL). The encoded protein is present on leukemic cells of pre-B phenotype, which represent 85% of cases of ALL. This protein is not restricted to leukemic cells, however, and is found on a variety of normal tissues. The protein is a neutral endopeptidase that cleaves peptides at the amino side of hydrophobic residues and inactivates several peptide hormones including glucagon, enkephalins, substance P, neurotensin, oxytocin, and bradykinin.




Images

MME  AntibodyFlow cytometry: 1×10^6 A549 cells (negative control,left) and U-138MG cells (right) were surface-stained with PE Rabbit anti-Human CD10 mAb (A25723,5 μl/Test,orange line) or PE Rabbit IgG isotype control(A24172,5 μl/Test,blue line). Non-fluorescently stained cells were used as blank control (red line).
Flow cytometry: 1×10^6 U-138MG cells were surface-stained with PE Rabbit IgG isotype control(A24172,5 μl/Test,left) or PE Rabbit anti-Human CD10 mAb (A25723,5 μl/Test,right).
Flow cytometry: 1×10^6 A549 cells (negative control,left) and Daudi cells (right) were surface-stained with PE Rabbit anti-Human CD10 mAb (A25723,5 μl/Test,orange line) or PE Rabbit IgG isotype control(A24172,5 μl/Test,blue line). Non-fluorescently stained cells were used as blank control (red line).
Flow cytometry: 1×10^6 Daudi cells were surface-stained with PE Rabbit IgG isotype control(A24172,5 μl/Test,left) or PE Rabbit anti-Human CD10 mAb (A25723,5 μl/Test,right).
Flow cytometry:1×10^6 Human Neutrophile granulocytes were surface-stained with APC Rabbit anti-Human CD66b mAb (A26616,5 μl/Test) and PE Rabbit anti-Human CD10 mAb (A25723,5 μl/Test,right) or PE Rabbit IgG isotype control (A24172,5 μl/Test,left).



You may also be interested in:

MME

Related Products


LifeSct © 2025

Publications

text_heading

Our Location

405 East Gude Dr., Suite 205, Rockville, MD 20850, USA

1-301-890-6420